AUTOCLAVE GALLERY
AUTOCLAVE INVASIVE MAINTENANCE (TUTTNAUER 2340M)
Machine has gone through years of no maintenance or service to the extend that functional operations have seized or significantly slowed • Machine would no longer drain • Switches no longer activating • Use of 'Ohm reader' on circuit board required to identify power usage intervals • Machine disassembly • Lubrication of hinges • Rethreading pipe seals • Invasive cleaning • Preventative parts were restored • Others parts were replaced • Chemical and vigorous cleaning to remove calcification • Grime and biofilm removed to restore stainless steel shine • Class 5 Integrator Chemical Testing • Biological Indicator (Spore Count) Testing • Multiple cycles needed to flush chemicals • Machine is ready for use again, hopefully for many more years to come
|
|
AUTOCLAVE INVASIVE MAINTENANCE (PELTON & CRANE OCR)
Machine has gone through years of no maintenance or service to the extend that functional operations have seized or significantly slowed • Machine would no longer drain • Switches no longer activating • Use of 'Ohm reader' on circuit board required to identify power usage intervals • Machine disassembly • Lubrication of hinges • Rethreading pipe seals • Invasive cleaning • Preventative parts were restored • Others parts were replaced • Chemical and vigorous cleaning to remove calcification • Grime and biofilm removed to restore stainless steel shine • Class 5 Integrator Chemical Testing • Biological Indicator (Spore Count) Testing • Multiple cycles needed to flush chemicals • Machine is ready for use again, hopefully for many more years to come
AUTOCLAVE INVASIVE MAINTENANCE (*OLD* TUTTNAUER 2340M)
Customer request for cleaning and update on mechanical functions • Preventative maintenance replaces broken or worn parts like filters, gaskets, and lids • Other components are restored to a 'like new' condition using all original materials • Complete restoration and calibration of system functions • Upon inspection, significant blockage was discovered due to a 'bug' and 'broken' materials blocking drain passage • Chemical and Biological Indicators all passed • Completed service report with all system timings presented to customer.
AUTOCLAVE INVASIVE MAINTENANCE (TUTTNAUER 2340M)
Customer request for cleaning and update on mechanical functions • Preventative maintenance replaces broken or worn parts like valves and gaskets • Other components are restored to a 'like new' condition using all original materials • Complete restoration and calibration of system functions • Upon inspection, significant blockage was discovered due to a 'hair' and 'debris' materials blocking drain passage • Chemical and Biological Indicators all passed • Completed service report with all system timings presented to customer.
AUTOCLAVE INVASIVE MAINTENANCE (*OLD* RITTER/MIDMARK M9)
Older unit customer had asked for a check-up on • Machine has significant age and wear • Use of 'Ohm reader' on circuit board required to identify power usage intervals • Machine disassembly • Lubrication of hinges and latches • Rethreading pipe seals • Invasive cleaning • Preventative parts were restored • Others parts were replaced • Chemical and vigorous cleaning to remove calcification • Grime and biofilm removed to restore stainless steel shine • Class 5 Integrator Chemical Testing • Biological Indicator (Spore Count) Testing • Multiple cycles needed to flush chemicals • Machine is ready for use again, hopefully for many more years to come
AUTOCLAVE INVASIVE MAINTENANCE (*DISCONTINUED* OMEGA ST)
Old obsolete autoclave (sterilizer) that had not been used in years with parts that are no longer in production • Machine would intermittently 'short' and had years of build up from 'dirty' wraps and non-distilled water • Testing and exploration to diagnose issues • Use of 'Ohm reader' on circuit board required to identify shorts at high power usage intervals • Machine disassembly • Lubrication of hinges • Rethreading pipe seals • Invasive cleaning • Preventative parts were restored rather than replaced because items are no longer available • Chemical and vigorous cleaning to remove calcification and grime and restore stainless steel shine • Class 5 Integrator Testing • Multiple cycles needed to flush chemicals • Machine is ready for use again, hopefully for many more years to come